Belts must be tensioned differently depending on their condition (flat belts, V-belts, toothed belts, etc.).
However, the following rule applies to most belts:
The drive belt may move when the tension is correct and the lateral pressure is 2 kg. Let the belt compress approx. 2mm.
If you have any questions about belt tension, please contact the Holzmann customer service (after-sales service or workshop)
400V machines always must be connected with 3 phases and one grounding.
With 4-wire wiring, the neutral conductor is omitted, with 5-wire wiring, a neutral conductor must also be connected (please also note this for any extra used extension cables)!
400V motors running only on 2 phases get hot very quickly and thus trigger the overload protection or break.
Please check the electrical connection and the supply line of your machine (also a possibly used extension cable).
400V machines always must be connected with 3 phases and an earthing.
With 4-wire wiring, the neutral conductor is omitted, with 5-wire wiring, a neutral conductor must also be connected!
400V motors running only on 2 phases become very hot quickly and thus trigger the overload protection or break.
Please also check if possibly present drive belt is sufficiently tensioned.
Please check if you are sufficiently fused for the machine used. 230V machines with a high motor power or high starting current require a 16 amp fuse with class C tripping characteristic "slow blow".
If you are not equipped with a C-16 fuse, please contact an electrician. Work in the distribution box may only be carried out by a specialist.
These are the rated operating modes of electric motors. A rated operating mode is a basic description of the load on an electrical machine. The nominal operating modes are defined in the international standard IEC 60034-1, which corresponds to the European standard EN 60034-1 and various national standards.
Since it would be uneconomical to design all machines for every conceivably difficult task, nominal operating modes have been defined in order to be able to clearly identify both a suitability for difficult conditions and a restriction to particularly light tasks.
S1 = continuous operation with constant load, S6 = periodic operation with load and speed changes (cooling phases).
Please note that these specifications always refer to one and the same motor and that these machines are not offered with different motors.
The following oils can be used for the 4-stroke engines of the Zipper machines.
15W40, 10W40, 10W30, SAE30
Both filler openings serve the same purpose. The engine is installed reversed on other models, so there must be a filler opening on both sides of the engine.
This hose can be used to drain the oil when changing the oil.
The transmission of our minidumpers is not synchronized, therefore it might happen that the gears are a bit harder to shift. This has nothing to do with a defect. Please note that the gears should only be engaged when the dumper is standing still.
The steering effect can be adjusted and balanced on the thread of the cables.
Please check the adjustment of the clutch cable. If it is not due to the adjustment, the V-belt must be tightened by moving the engine (slotted holes on the base plate).
400V machines must always be connected with 3 phases and a ground.
With a 4-wire wiring the neutral conductor is not needed, for 5-wire wiring a neutral conductor must be connected (Please note this also for any extension cables which may be used)!
400V motors that only run on 2 phases get hot very quickly and thus trigger the overload protection or break down.
For the further steps of commissioning the log splitter, please refer to the operating instructions.
Please check the electrical connection and the supply cable of your machine (also the extension cable if it is used).
400V machines must always be connected with 3 phases and the ground.
With a 4-wire wiring the neutral conductor is omitted, with a 5-wire wiring also a neutral conductor must be connected!
400V motors that only run on 2 phases get hot very quickly and thus trigger the overload protection or break down.
Please check also with a possibly existing drive belt whether this is sufficiently tightened.
Please check the electrical connection and the supply cable of your machine (also the extension cable if it is used).
400V machines must always be connected with 3 phases and the ground.
With a 4-wire wiring the neutral conductor is omitted, with a 5-wire wiring also a neutral conductor must be connected!
400V motors that only run on 2 phases get hot very quickly and thus trigger the overload protection or break down.
Please check also with a possibly existing drive belt whether this is sufficiently tightened.
Please check if you are adequately protected for the machine you are using. 230V machines with a high motor power or high starting power, need a 16 ampere fuse with a tripping characteristic of class C "wear fuse".
If you do not have a C-16 fuse, please contact an electrical company. Working in the distribution box may only be carried out by a specialist.
.
For these applications, it is essential to consult an electrician for inspection. If you are working with sensitive devices or controls, use an inverter..
Before buying a generator, you should check the rated power of the consumers (nameplate watts or KW information) which you want to connect and plan reserves. For inductive loads (e.g.: pumps, saws, drills,...) a significantly increased power can be required for the start ( ca 3 x higher), which can activate the overload protection of the generator (especially if it is at the design power limit).
YES - The battery is included in all generators with an electric starter.
ATTENTION: Please do never use the power generator in closed rooms, this is an extreme danger to life because of the exhaust fumes. Even if you want to discharge the exhaust gases, you will not be able to completely prevent some of it from escaping. We do not carry connectors for exhaust gas discharge and clearly point out that the power generator has not be used in closed rooms.
Operation with fuel oil is not recommended because fuel oil has a higher sulfur content than diesel. In addition, there are no minimum requirements regarding the cetane number for fuel oil (describes the ignitability of the fuel), which could lead to strong nailing and soot emission.
Please check if you are adequately protected for the machine you are using. 230V machines with a high motor power or high starting power, need a 16 ampere fuse with a tripping characteristic of class C "wear fuse".
If you do not have a C-16 fuse, please contact an electrical company. Working in the distribution box may only be carried out by a specialist.
Please be sure to follow the starting order and instructions in the user manual. For further questions, please feel welcome to contact our customer service.
Please do not start shredding until the shredder has reached full engine speed. This also applies between fillings. Ensure that all residues are removed after you have finished shredding.
The ZI-DOP600 pump is only suitable for diesel and fuel oil.
400V machines must always be connected with 3 phases and a ground.
With a 4-wire wiring the neutral conductor is not needed, for 5-wire wiring a neutral conductor must be connected (Please note this also for any extension cables which may be used)!
400V motors that only run on 2 phases get hot very quickly and thus trigger the overload protection or break down.